1 - EPROM checksum test failure.

Skip Navigation LinksSupport > Knowledge Base > XL200 Series Controllers > Error Codes > 1 - EPROM checksum test failure.


When powering up, the controller checks the boot code and operating system stored in the Flash EPROM.  If certain codes don't match, this error will result.

Cause

  1. This error is usually seen after attempting to flash new software into the controller.  During the flash download process, some data was corrupted due to poor transmission quality.

  2. A board-level hardware failure has corrupted the data in the controller Flash EPROM.

 Remedy

  1. Re-attempt the software flash.
    • If flashing software from a laptop, be sure the laptop is on AC power and not battery power.  Many laptops go into a "power save" mode while on battery power.  The COMM ports on the laptop could be operating at a lower power level.
    • Try using a shorter communication cable.  This cable length should be ≤ 6' (1.8 m).
    • Be sure to remove the "B" connector from the back of the XL200 controller.  Eclipse communication can interfere with the flash process.

  2. Contact AMS Controls Technical Support for a repair.