Press X Dwell Up


Press Dwell Up defines the time a specified press’s die takes to return the up position from the down position.

Each press on the machine has a dwell time programmed to define the duration of each press cycle, between 0.001 to 9.999 seconds.

Note: On boosted Flying Die machines, a Press Boost Output replaces the Press Up output, so no Press Dwell Up parameter is required.

The actual press output activates for the programmed dwell time. On feed-to-stop lines, this movement is detected as a pause.