Velocity at Maximum Analog allows the controller to provide an analog output proportional to line speed measured by the line encoder. The range for this parameter is 0 to 1000 FPM.
The default setting 0 disables this feature.
After you program the maximum velocity in Feet Per Minute (FPM), the controller outputs 10 VDC (defined for Analog Output #1 on the XL200 Series controller) at line speeds equal to or greater than this parameter. As speed decreases, the output is scaled down linearly until zero FPM is equal to zero volts DC.